Skid-Mounted Diesel Filtration · VFD Adjustable Flow · Multi-Precision Optional

JY-DX40 Skid-Mounted Diesel Fuel Filtration System40 m³/h Rated · 10–40 m³/h VFD-Adjustable

Up to 40 m³/h rated flow, with VFD-adjustable operation from approximately 10–40 m³/h — one standardized skid for diesel storage tanks, fuel depots, mining operations, generator fuel systems and industrial fuel storage.

Direct Answer

The JY-DX40 is a skid-mounted diesel fuel filtration and polishing system rated at 40 m³/h, with 8 independent CIS rigid composite membrane groups for fuel depot, refinery and industrial duty. With a variable frequency drive (VFD), operating flow can be adjusted to actual requirements — an approximate operating range of 10–40 m³/h from one standardized skid. CIS rigid composite membrane achieves capture efficiency ≥98% @ ≥5 µm (optional 2/5/10/15/20 µm) with simultaneous free-water removal ≥95% and 30-second gas-pulse regeneration, no disposable filter cartridges.

40 m³/h rated flowVFD-adjustable approx. 10–40 m³/hCIS rigid membraneNo disposable cartridges
JY-DX40 skid-mounted diesel fuel filtration system — 40 m³/h rated flow, VFD-adjustable 10–40 m³/h
JY-DX40 photo 1JY-DX40 photo 2JY-DX40 photo 3JY-DX40 photo 4JY-DX40 diagram 5
40 m³/hRated flow
≈10–40 m³/hVFD-adjustable operating range
8 groupsRigid membrane modules
30 secPneumatic backwash flux recovery
Layer 1 · Quick Specification

30-second specification check.

ModelJY-DX40Membrane fine filtration skid
Rated flow40 m³/hHigh flow
VFD adjustable operating rangeApprox. 10–40 m³/hWith optional VFD; depends on operating conditions
Power configuration7.5 kW centrifugal pump set (380V/50Hz)Booster unit
Control configurationManual standard; VFD flow control / automated control optionalMatch operating duty
Filtration precisionCapture efficiency ≥ 98% @ ≥ 5 µm; optional 2/5/10/15/20 µmMultiple precision options
Maximum working pressure0.5 MPa (operating 0.2–0.4 MPa)Safe operation
Fluid temperature range0 ~ 70°CApplicable range
Applicable mediumDiesel (kinematic viscosity < 68 cSt)Flash point ≥38°C
Main body materialCarbon steel standard; stainless steel optionalDurable
Seal materialViton fluoroelastomerHigh reliability
Anti-corrosion gradeC3Industrial grade
Engineering interfaceInlet/outlet DN80 (3") / petrochemical quick connectorStandardized
Gas source interfaceExternal 0.5~0.7 MPa clean gas sourceFast backwash
Dimensions2700 × 1400 × 2040 mmSkid-mounted
Dry weight1500 kgStable
FootprintApprox. 3.78 m²Modular
Application boundary: Only suitable for diesel with flash point ≥38°C; gasoline and other low-flash-point media are strictly prohibited. A dry clean gas source is recommended for backwash, and static grounding must follow site requirements.
VFD Flow Control

One skid, multiple operating flow rates.

JY-DX40 · 40 m³/h rated flow
▼  VFD speed control
Adjustable operating flow (approx.)
5 m³/h40 m³/h
One skid · Multiple operating conditions
  • 1
    Requirements vary

    Fuel filtration requirements are not always constant. Tank volume, fuel condition, contamination level and operating schedules can differ significantly from one application to another.

  • 2
    VFD adjusts pump speed

    The JY-DX40 can be equipped with a variable frequency drive (VFD), allowing the operator to adjust pump speed and filtration flow according to actual operating conditions.

  • 3
    One skid, approx. 10–40 m³/h

    Instead of purchasing separate filtration systems for different flow requirements, one JY-DX40 provides an approximate operating range of 10–40 m³/h, subject to fuel properties, filtration precision, system pressure and operating conditions.

How It Works

Process & regeneration.

JY-DX40 membrane separation flowchart
  • 1
    Contaminated diesel in

    Water, sludge and particulates enter with the fuel stream.

  • 2
    CIS membrane separation

    Rigid composite polymer membrane captures particles and strips free water.

  • 3
    Gas-pulse regeneration

    Compressed air clears the membrane surface — no cartridges.

  • 4
    Clean diesel out

    Fuel returns at target cleanliness.

Typical Operating Conditions

Flexible flow for different operating conditions.

Low-flow circulation

Approx. 10–20 m³/h

Suitable for small storage tanks, slow circulation filtration, routine fuel polishing, and heavily contaminated fuel that benefits from controlled, lower-flow processing.

Medium-flow filtration

Approx. 20–30 m³/h

Suitable for medium-size diesel tanks, routine fuel purification, mining fuel storage, generator fuel systems and industrial fuel storage.

High-flow operation

Approx. 30–40 m³/h

Suitable for fuel depots, tank transfer operations, large diesel storage tanks, faster filtration cycles and higher-throughput industrial applications.

Flow disclaimer: Actual achievable flow depends on fuel viscosity, temperature, contamination level, selected filtration precision, system pressure and other operating conditions. The ranges above are indicative operating windows, not guaranteed values for every fuel or filtration condition.
Why Adjustable Flow Matters

A filtration system does not always need maximum flow.

Running at a lower flow rate can be useful when treating smaller tanks, heavily contaminated fuel or applications requiring longer contact and controlled filtration conditions.

Higher flow rates can be selected when faster tank turnover or higher processing capacity is required.

With VFD control, the JY-DX40 provides this flexibility without requiring a different skid for every flow requirement.

Small tank

→ Lower flow for gentle, controlled treatment

Normal operation

→ Medium flow for routine purification

Large tank / faster turnover

→ Higher flow for shorter processing cycles

Applications

Who is the JY-DX40 designed for?

Fuel depots

For diesel storage and circulation filtration where different tank sizes require different processing rates — including tank-farm circulation and transfer-line duty.

Mining operations

For diesel storage and fuel management at mining sites, where a skid-mounted system provides mobility and operational flexibility.

Generator fuel systems

For diesel polishing and storage-tank circulation where continuous or periodic filtration is required, including base-load generator duty.

Industrial fuel storage

For factories, engineering facilities and other industrial users requiring flexible fuel purification capacity.

Gas stations

For storage tank maintenance and diesel quality management, subject to site configuration and local requirements.

Standards & Compliance

Layer 4 · Compliance basis.

  • Filtration performance based on ISO 16889
  • Static grounding requirement: resistance ≤10Ω
  • Dry nitrogen is recommended for backwash gas
  • Hazardous waste disposal should comply with HW08/HW09 requirements
  • Explosion-proof motor and explosion-proof electrical switches as standard
  • C3 anti-corrosion grade for port and industrial environments
Procurement Value

One system instead of multiple fixed-flow units.

For customers with changing or uncertain fuel-processing requirements, a VFD-equipped JY-DX40 can provide greater operating flexibility than a fixed-speed filtration system.

The same skid can be adjusted for different tank sizes and operating conditions, helping customers avoid purchasing multiple filtration units solely because their required flow rates vary — improving equipment utilization and enabling scalable operation from a single standardized skid.

Budget-Conscious Procurement

A practical option for budget-conscious buyers.

Customers do not always know their long-term fuel filtration requirement when purchasing their first system.

A VFD-equipped JY-DX40 provides a practical middle-capacity solution: the system can operate at lower flow rates when demand is limited and increase the flow rate as processing requirements grow.

This can be particularly useful for customers who want to start with one versatile skid-mounted filtration system rather than purchasing several fixed-flow units.

Selection Guidance

Is JY-DX40 the right size for your application?

Consider JY-DX40 if

  • Required flow is up to approximately 40 m³/h
  • You need different operating flow rates from one system
  • Tank sizes vary across your site
  • You want a skid-mounted, compact industrial filtration solution
  • You want VFD-based flow control
  • Processing requirements may increase in the future

Consider a smaller system if

  • Required flow is consistently below approximately 5 m³/h — see JY-DX5
  • Applications are limited to very small tanks
  • Portability is more important than throughput — see JY-G100 mobile

Consider a larger system or duty/standby configuration if

  • Required continuous flow exceeds 40 m³/h — see JY-DL60
  • The application is mission-critical
  • Filtration cannot be interrupted for backwash
  • Multiple tanks must be processed simultaneously
Engineering note: Required continuous flow above 40 m³/h does not automatically rule out the JY-DX40 — multi-skid or duty/standby configurations depend on the actual project. Need containerised field deployment with minimal civil works? See the JY-Q325 containerised station. Typical JY-DX40 duties include refinery transfers, tank-farm circulation and generator base-load polishing.
FAQ

JY-DX40 — frequently asked questions.

Is the JY-DX40 fixed at 40 m³/h?

No. 40 m³/h is the rated flow capacity. When equipped with a VFD, the operating flow can be adjusted according to actual application requirements, with an approximate operating range of 10–40 m³/h.

Can the JY-DX40 operate at 10 m³/h?

Yes. With VFD control, the system can operate at a lower flow rate when required. Actual achievable flow depends on fuel properties, filtration precision, pressure and operating conditions.

Can one JY-DX40 handle different tank sizes?

Yes. VFD flow adjustment allows the same skid to be operated at different flow rates according to tank size and processing requirements.

What is the maximum flow of the JY-DX40?

The rated flow is 40 m³/h. Actual operating flow may vary depending on fuel properties, filtration precision and system operating conditions.

Why use a VFD on a fuel filtration system?

A VFD allows pump speed and filtration flow to be adjusted according to actual operating requirements, providing greater flexibility than a fixed-speed configuration.

Is 5 m³/h guaranteed under all conditions?

No. The approximate 10–40 m³/h operating range should not be interpreted as a guaranteed flow under every fuel and filtration condition. Actual performance depends on fuel viscosity, temperature, contamination level, filtration precision, pressure and other system conditions.

Is JY-DX40 suitable for small or medium-sized fuel storage applications?

It can be suitable when the required filtration capacity is within its operating range. VFD control allows the system to operate at lower flow rates when full capacity is not required.

Can the JY-DX40 be used for diesel fuel polishing?

Yes. The JY-DX40 can be configured for diesel fuel filtration and polishing applications. The appropriate filtration precision and system configuration should be selected according to the fuel condition and required cleanliness level.

How long is the membrane module service life?

Designed service life is 2–3 years. Fast backwash significantly lowers operation and maintenance cost.

How long does backwash take?

Only 30 seconds of gas-pulse backwash restores initial flux to over 95%.

Does it require complex civil installation?

No. The standardized skid design enables quick site connection and commissioning.

Is it suitable for low-flash-point media?

It is only suitable for diesel with flash point ≥38°C. Gasoline and similar media are strictly prohibited.

How effective is free-water removal?

Free-water removal efficiency reaches ≥95%. Dissolved water is not removed.

Is customization supported?

Yes. Stainless steel material, automated control and other flow/interface configurations are available.

Lineup

Other systems in the range.

Field Evidence

JY-DX40 in operation: three systems deployed across a multi-depot fuel network in West Africa — inline loading-pump filtration, ISO cleanliness 24/22/19 to within 15/13/10 per customer site records. A further JY-DX40 provides 40 m³/h beside-tank circulation polishing at a Shandong new-energy company, intercepting micron-scale gum and oxidised resin.

West Africa Multi-Depot Case → Shandong Refining Case →
Engineering Support

Need help selecting the right flow rate?

Tell us your tank volume, fuel type, required filtration precision and expected processing time. We can help determine whether the JY-DX40 and its VFD configuration are appropriate for your application.

Request JY-DX40 Technical Information Ask About JY-DX40 Configuration

Looking for a flow rate below the standard JY-DX40 configuration? Explore our custom-flow skid solutions for approximately 3–20 m³/h applications, configured by engineering evaluation.

Custom Flow 3–20 m³/h →

Request selection & quotation — JY-DX40

We reply within one business day with a matched system recommendation and budget figure. No obligation.

Request a Quote